Home  |  Mission Statement  |  Certification  |  Contact Us  |  Site Map    
PRODUCTS & SERVICES
 Hose Protection and Containment
Reusable Hose/Cable Sleeving (Sidewinder)
Hose/Cable Sleeve Protection (Diamondback)
Hanging Straps
Cinching Straps
 Compressed Air Systems
Air Dryer
Aftercooler
Automatic Moisture Separator
Breathable Air Grade D
Oil Coalescer Filter
Regulators
Lubricators
Particulate Filter with Regulator
Automatic Piston Drain Valves
Solenoid Drain Valves
 Automatic Chain Oilers - Lube Minder kits
John Deere
CNH - Case - International - New Holland
Gehl - AGCO
Meyer Manure Spreaders
Vermeer
Lube Minder custom oiling systems
 Contract Manufacturing
Precision Machining
Contract Assembly
Facilities List
Vector Tool Division
Featured Product
Suburban has developed a unique solenoid drain valve that will revolutionize the marketplace. Available for immediate delivery!

• Adjustable Cycle
• Built in, Self Cleaning stainer
• Easy Installation
• Discharges up to 25 gallons/hour.

Compliments receiver tanks and compressors up to 300 hp

US Patent 6,571,830 : EPO 01306857.2

READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION

WARNING

BEFORE SERVICING OR WORKING ON ANY COMPRESSED AIR SYSTEM COMPONENTS, USE THE MANUFACTURE’S MANDATORY SAFETY SHUT DOWN PROCEDURE FOR ALL COMPONENTS.

THIS INCLUDES DISCONNECTING ELECTRICAL POWER AND USING REQUIRED SAFETY LOCKOUT TAGS.

AIR PRESSURE IN SYSTEM MUST BE BLED DOWN TO ZERO-ALWAYS USE THE PRESSURE GAGE TO VERIFY.

SAFETY GLASSES MUST BE WORN.

A LICENSED ELECTRICIAN MUST DO ALL ELECTRICAL WORK, AND ALL STATE AND LOCAL CODES MUST BE FOLLOWED.

TEFLON PIPE SEALANT SHOULD BE USED ON ALL PIPE FITTINGS.

NOTE: IF YOU NEED HELP WITH ASSEMBLY INSTRUCTIONS PLEASE CALL TOLL FREE 1-800-782-5752 AND ASK FOR THE ENGINEERING DEPARTMENT.

install002white.jpg (38457 bytes)

mmone installation.gif (11546 bytes)

The Moisture Minder® drain valve is a unique product for automatically draining condensed water and oil from air compressors up to 30 hp. The pressure drop and air loss normally associated with float, electric solenoid or diaphragm valves is not present. The Moisture Minder® can be mounted above the bottom of the tank on the wall or on the motor-pump base plate, this allows for easier installation. The valve is operated by teeing into the unloader line and is actuated every time the compressor cycles on and off. When the compressor is running, air pressure from the unloader line actuates a internal piston and ball check assembly that allows water to enter the valve from the bottom of the tank, this water is forced up into the stainless tank on top of the drain valve. When the compressor shuts off and pressure is bled away from the unloader line the, stored water in the stainless tank is ejected

Mounting the drain valve: install the fittings as shown in photo #1. Note the short pieces of tubing shown are for reference only.

¼” straight male connector

90 degree elbow fittings (2)

¼” tee (note install brass tube inserts into end of nylon tube before installing, to prevent crushing of tube

1/8” straight male connector for drain line

install003.jpg (34514 bytes)

When mounting the drain valve to the compressor - motor/pump base plate

Drill a ¼” diameter hole and mount the clamp bracket to base plate as shown with a ¼” cap screw, lock washer and nut. (See photo # 2)

When mounting the drain valve to a wall. Pick a spot that is high enough to get a 5-gallon pail underneath the valve. Drill a 5/16” diameter hole for the plastic wall anchor. Install the wall anchor and secure bracket with the screw. (See photo #3)

Install the drain valve in the clamp and secure. Connect the tubing from the strainer fitting (#1) to the water inlet side of the drain valve (#2). For compressors that have a pressure switch unloader, the tee fitting (#3) needs to be spliced into the unloader line figure (C.). Compressors that have a centrifugal unloader, the tee will need to be spliced in at location (D). Next connect the nylon tubing from this tee and connect to the elbow fitting on the air signal side of the drain valve. The 1/8” fitting may be installed in the drain or discharge port of the valve and routed to a pail or directly to a drain. (Note check with state ordinances about proper disposal of compressor condensate).

install004.jpg (34188 bytes)
 
 