Regenerative Dryer Installation FAQS
Tips to help with dryer installation.
Single bracket (10 and 15 HP): 75 lbs
Dual Bracket (20 and 30 HP): 150 lbs
When installing the 15, 20, and 30 HP units, it's best to use two people to mount the dryers
Install the JIC swivel adapter at the outlet of the pre-filter assembly, then install the JIC adapter into the dryer inlet.
Use appropriate thread adhesive or thread sealant tape when installing the adapters.
Finally, connect the pre-filter assembly to the dryer using the swivel fitting.
Cut the included black drain tubing to the desired length and connect it to the push-in fittings on the filter drains.
Then route the tubing downward from the automatic drains to a suitable discharge location, such as a bucket or floor drain.
Route the tubing to a bucket or a drain to properly discharge the condensate and collected oils from the air filters as the dryer cycles.
Yes, a bypass system is required and should be installed as part of the compressed air system plumbing before installing the dryer.
It allows compressed air to continue flowing to the facility when the dryer needs to be isolated for maintenance.
To bypass the dryer:
1. Open the bypass valve, then close the downstream and incoming air valves. This redirects compressed air around the dryer and maintains airflow to the facility.
2. Once the dryer is isolated, open the appropriate valves to release pressure from the dryer before performing maintenance.
Yes. When a properly installed bypass system is used, compressed air can continue flowing to the facility while the dryer is isolated for maintenance.
The bypass valve redirects airflow around the dryer, allowing the system to remain operational during servicing.